Dcm2niix and recent Siemens software release (XA60)
|
|
1
|
53
|
April 23, 2024
|
BOLD_NOT_4D for one particular run (converting both single band and multi band files)
|
|
3
|
47
|
April 18, 2024
|
Dcm2bids dcm2niix more runs than expected
|
|
10
|
61
|
April 15, 2024
|
Specifying dcm2niix version used in Nipype
|
|
2
|
88
|
April 8, 2024
|
Dcm2bids produces bvec/bval with string of 0s for bold data
|
|
5
|
168
|
February 14, 2024
|
No magnitude file are detected for fieldmap for dti
|
|
0
|
101
|
January 31, 2024
|
Dcm2bids trouble with duplicates
|
|
3
|
127
|
January 25, 2024
|
Dcm2niix error using heudiconv
|
|
1
|
308
|
September 15, 2023
|
Dcm2bids - New release 3.1.0
|
|
0
|
452
|
September 14, 2023
|
Slicetiming warning on AP/PA sequences when using dcm2niix on Siemens XA30 data
|
|
2
|
374
|
September 6, 2023
|
Dcm2niix no longer extracts EchoTrainLength?
|
|
1
|
193
|
September 6, 2023
|
Dcm2bids - New release - 3.0.2
|
|
0
|
408
|
August 31, 2023
|
Slice timing in diffussion
|
|
5
|
268
|
August 16, 2023
|
Convert GE pepolar diffusion scan to BIDS format
|
|
1
|
275
|
August 3, 2023
|
Dcm2niix identifying EPI orientation incorrectly?
|
|
8
|
731
|
May 4, 2023
|
Functional data DICOMS converting to 3d images instead of 4d
|
|
10
|
549
|
April 7, 2023
|
Dcm2niix does not extract the tag 'PhaseEncodingDirection' for fieldmaps
|
|
1
|
601
|
February 19, 2023
|
Total Readout Time for fMRIPREP with topup on Philips scan data, possible dcm2niix error
|
|
2
|
851
|
January 3, 2023
|
DCM2NIIX splitting a scan run into multiple files
|
|
8
|
3831
|
December 9, 2022
|
Adjusting for negative MosaicRefAcqTimes (issue 271) despite latest version of dcm2niix
|
|
1
|
443
|
November 30, 2022
|
Unsupported transfer syntax MRIcroGL v1.2.20220720
|
|
4
|
623
|
October 10, 2022
|
Difference in ReconMatrixPE between dcm2niix versions v1.0.20181125 GCC4.8.5 and v1.0.20220720
|
|
4
|
487
|
September 8, 2022
|
How dcm2niix handles different imaging types
|
|
11
|
1169
|
June 9, 2022
|
Deface on DICOM files
|
|
2
|
1371
|
May 27, 2022
|
fMRI PREP: FileNotFoundError: [Errno 2] No such file or directory: 'dcm2niix'
|
|
2
|
934
|
April 14, 2022
|
DCM conversion to Nii with missing slices (instances)
|
|
1
|
763
|
January 18, 2022
|
Unsure about why previous two versions of dcm2niix give different values for slicetiming field of GE dataset
|
|
3
|
535
|
January 6, 2022
|
Is there a way to loop through multiple sub-folders with dcm2niix + create BIDS structure?
|
|
8
|
2826
|
December 23, 2021
|
Slice Time and bids-validator problems with Philips scanner Dicoms
|
|
7
|
880
|
December 16, 2021
|
Dcm2niix outputs NIFTI in unzipped format (.nii) and not in nii.gz format
|
|
4
|
1835
|
September 25, 2021
|